Plant
At the
plant we check the proportioning of mix components
for compliance with the specifications. Air content,
slump, and temperature tests are performed as needed.
Mix designs are reviewed.
|
|
|
Field
In the field,
placement procedures are observed and documented.
Temperature, slump, and air content are monitored,
and sets of cylinders are cast for compressive strength
testing.
|
Laboratory
Concrete cylinders
are logged, cured in our moisture room, and tested for
compressive strength at prescribed ages.
|
|
|